Microscopic analyses showed that, owing to the heavy load and the unbalanced nutrient ratio, filamentous bacteria had been able to proliferate massively.

Michael Kocher, the VTA technician working on this case, therefore recommended the use of VTA Nanofloc®.

In Germany, it’s the ‘favourite drink of the urban eco-elite’ (according to Der SPIEGEL magazine), and can be considered the alternative model to traditional soft drinks: Bionade, produced purely biologically by a brewing process according to a recipe that is unique worldwide. ‘With its clean products, VTA’s approach fits perfectly with our company philosophy,’ says Theo Flögel, who takes care of wastewater treatment at Bionade GmbH in the town of Ostheim vor der Rhön in Lower Franconia, Bavaria.

Bees as a role model

From zero to one hundred ... doesn’t quite describe the meteoric rise of the fizzy cult drink, because it actually took off from below zero. A small Ostheim brewery called Peter was on the verge of going under when, after years of research, then co-owner Dieter Leipold succeeded in 1995 in turning an ingenious idea into a marketable product. Sneered at initially by experts, the master brewer actually managed to use a new biological process based on the principles of brewing to convert sugar into digestible gluconic acid during fermentation, rather than into alcohol as is usually the case. It is a principle he has basically learned from bees: in honey production, gluconic acid is also produced from sugar.

From 2 million to 200 million bottles

After some initial teething problems in opening up the market, the Bavarians made the breakthrough with their Bionade in Hamburg of all places. The eco-scene in the Hanseatic city was the first to discover the organic thirst quencher, which according to the manufacturer contains 30% less sugar than conventional soft drinks, and is therefore also lower in calories. What began as an insider’s tip in Hamburg grew at an unbelievable pace to become a trendsetter in the German beverage market: where Bionade GmbH filled two million bottles per year in 2002, its founding year, this figure had grown one-hundred-fold by 2007.

The tearing pace of growth at the small brewery soon brought both its production facilities and its old treatment plant to the limits of their capacities. The new SBR plant, on the other hand, which went into operation in 2009, had sufficient reserves – capacity could be doubled if required without any major conversions.

COD values up to 3,000 mg/l

On average, some 300 up to a maximum of 600 cubic metres of wastewater with a COD concentration of 2,000 to 3,000 mg/l were produced per day. Had this inflow been uniform, Theo Flögel, the technician responsible for the treatment plant, wouldn’t have had a problem. But as is often the case, wastewater is produced only during Monday to Friday operations. In addition to the resulting fluctuating COD concentrations, the biological stage also had to cope with high pH values. While an equalisation basin may be able to absorb peak loads, it cannot guarantee a uniform feed.

Even months after the start of operation, the new treatment plant was still not stable. No sooner were there signs of improvement than the next setback followed. Poor settleability, high COD discharge values and a growing blanket of scum prompted technical plant manager Wolfgang Bufe to consult VTA.

Lightning-fast improvement in settleability

The reason for the unsatisfactory operating result quickly became clear: microscopic analysis showed that because of the heavy loads and an unbalanced nutrient ratio, filamentous bacteria were proliferating. Michael Kocher, the VTA technician working on this case, therefore recommended the use of VTA Nanofloc®.

This special VTA product, known for its rapid and lasting effect, seemed to be tailor-made for it: the sludge sedimentation rate improved abruptly and the COD concentration in the discharge dropped from around 500 to below 100 mg/l within a few days. The scum also vanished.

Single-digit COD concentrations

Today, wastewater treatment is exactly as it should be, and the plant can now easily cope with unexpected fluctuations in inflow. Discharge values are better than ever before, while COD concentrations are in some cases down to the single-digit range – which means that Bionade now already just about meets the extremely stringent guidelines for direct dischargers.

Field report from the VTA Group’s scientific journal “Laubfrosch”, issue 50

 

Request

Would you like more information about our intelligent processes? 
Contact our experts and together we will find the right solution.

Contact

Auf Social Media teilen: